Voyager 1.0.23 New Release

us New release of Voyager ready to download … 1.0.23, look at download section.

⦁ [New] Adding Sequence Cooling tab in the possibility of self climb the temperature of the CCD in the event of initial failures to achieve with 3 different temperatures in automatic order
⦁ [New] Adding Sequence Cooling tab in the possibility of self climb the temperature of the CCD in the case of average power, the last time interval indicated above a certain percentage value
⦁ [New] Added Focuser Control Control Interface
⦁ [New] Added Focus Control Object ASCOM
⦁ [New] Added AutoFocus Control RoboFire (for now only focusing command in the AUTOFOCUS box rotary button called Facility)
⦁ [New] Added RoboFire setup to indicate the move steps of the Facility buttons and the virtual limits of focuser that Voyager cannot pass
⦁ [New] Focuser Move To Action Adds for Focuser Associated with AutoFocus Control
⦁ [New] Added Block to DragScript for Move To of Focuser connected to RoboFire Autofocus System
⦁ [New] Added DragScript Block for the precise focusing of the focus star selected using RoboStar
⦁ [Mod] Optimized display and readout data code to comply with Voyager Status Camera Statements for ASCOM and QSI Camera
⦁ [Bug] Saving FIT Control QSICamera ASCOM and in some special conditions of internal headerfit, the image data were corrupted
⦁ [Bug] Only for ASCOM wheels was not waited for the end of the movement of the filter wheel before starting shooting⦁ [Bug] Removed error for binning usage greater than 2 in ASCOM and QSI Camera
⦁ [Bug] Removed error for in GoodNight Script execution called from  the OnTheFly Section
⦁ [Bug] Removed error for in Sequence when autoscaling CCD temperature. In some condition the scaling happens in short time without reason and also can generate an indesired abort of all action

img_italia Nuova release di Voyager disponibile per il download .. 1.0.23 La trovate nella sezione download

⦁ [New] Aggiunta in Sequenza nel tab Cooling la possibilità di auto scalare la temperatura della CCD in caso di mancato raggiungimento iniziale con 3 temperature diverse in ordine automatico
⦁ [New] Aggiunta in Sequenza nel tab Cooling la possibilità di auto scalare la temperatura della CCD in caso di potenza media, nell’ultimo intervallo di tempo indicato, superiore ad un certo valore percentuale
⦁ [New] Aggiunta Interfaccia di Controllo Focuser Object
⦁ [New] Aggiunto controllo Focuser Object ASCOM
⦁ [New] Aggiunto controllo AutoFocus RoboFire (per ora solo comando focheggiatore nel box AUTOFOCUS pulsante rotellina detto Facility)
⦁ [New] Aggiunto in setup per il RoboFire la possibilità di indicare gli step di spostamento dei pulsanti Facility e i limiti virtuali che Voyager non può oltrepassare
⦁ [New] Aggiunta Azione Focuser Move To per il posizionamento del Focheggiatore associato al controllo AutoFocus
⦁ [New] Aggiunto Blocco a DragScript per lo spostamento del Focheggiatore connesso al sistema di autofocus RoboFire
⦁ [New] Aggiunto Blocco a DragScript per lo il solo puntamento preciso della stella di fuoco selezionata tramite RoboStar
⦁ [Mod] Ottimizzato codice di esposizione e lettura dei dati per rispettare le indicazioni nello Status Camera di Voyager per Camere ASCOM e QSI
⦁ [Bug] Salvataggio FIT Controllo QSICamera e ASCOM in alcuni condizioni particolari di headerfit interni, i dati immagine venivano corrotti
⦁ [Bug] Solo per le ruote ASCOM non veniva atteso il termine del movimento della ruota filtri prima di iniziare lo scatto
⦁ [Bug] Rimosso errore per utilizzo di binning superiori a 2 nelle Camere ASCOM e QSI
⦁ [Bug] Rimosso errore esecuzione script nel GoodNight chiamato dal tasto OnTheFly
⦁ [Bug] Rimosso errore in Auto Scaling della temperatura del CCD durante la sequenza che poteva portare ad un veloce scaling della temperatura con anche possibile abort dell’intera azione

Voyager 1.0.18 New Release

us New release of Voyager ready to download … 1.0.18, look at download section.

⦁ [New] From this version Voyager operates independently with camera QSI and ASCOM compatible (Moravian, QHY, Atik, Apogee, StarlightXpress, ZWO and others)
⦁ [New] From this version Voyager operates autonomously with internal QSI wheel and all-wheel ASCOM compatible
⦁ [New] Added FilterWheel ASCOM control
⦁ [New] Added Camera Control ASCOM
⦁ [New] Is possible now to set the waiting timeout launch of the external processes (default 3s) as PHD2 and Cartes Du Ciel before connecting them (one time set in setup -> Voyager -> External Process Starting)
⦁ [New] Added new block FLIP ROTATOR 180 ° to perform the flip of the rotator
⦁ [New] Added new ROTATOR MOVE TO block to perform arbitrary rotation angle indicated
⦁ [Mod] Added a warning message when you use the functions in OnTheFly with instrumentation controls unselected
⦁ [Mod] Optimized release of ASCOM controls used to disconnect and closing Voyager
⦁ [Bug] Failed to start the Cartes du Ciel process if it is installed as a 64bit on generally even though 32 in some of the PC load
⦁ [Bug] In the case of the initial waiting time in the sequence if there was also a height constraint of the subject was performed checking before having waited the start time required with possible immediate exit
⦁ [Bug] In case of non-use of the SUFFIX field (empty field) in FLAT with Color Camera or DSLR the FIT save generated a file error with inability to perform the FLAT

img_italia Nuova release di Voyager disponibile per il download .. 1.0.18 La trovate nella sezione download

⦁ [New] Da questa versione Voyager gestisce in autonomia camere QSI e ASCOM Compatibili (Moravian, QHY, Atik, Apogee, StarlightXpress,ZWO e altre)
⦁ [New] Da questa versione Voyager gestisce in autonomia le ruote interne QSI e tutte le ruote ASCOM Compatibili
⦁ [New] Aggiunto controllo FilterWheel ASCOM
⦁ [New] Aggiunto controllo Camere ASCOM
⦁ [New] E’ ora possibile impostare il timeout di attesa di avvio dei processi esterni (default 3s) come PHD2 e Cartes Du Ciel prima di connetterli (tempo unico impostabile in setup -> Voyager -> External Process Starting)
⦁ [New] Aggiunto nuovo blocco ROTATOR FLIP 180° per effettuare il flip del Rotatore
⦁ [New] Aggiunto nuovo blocco ROTATOR MOVE TO per effettuare rotazione arbitraria ad angolo indicato
⦁ [Mod] Aggiunti messaggi di warning in caso di utilizzo di funzioni in OnTheFly con controlli strumentazione non selezionati
⦁ [Mod] Ottimizzato rilascio dei controlli ASCOM utilizzati alla disconnessione e chiusura di Voyager
⦁ [Bug] Non veniva avviato il processo di Cartes Du Ciel se è installato come 64bit on in generale anche se a 32 in alcune condizioni di carico del PC
⦁ [Bug] In caso di attesa orario iniziale nella sequenza se vi era anche un vincolo d’altezza del soggetto veniva eseguito il controllo prima di aver atteso il tempo di start richiesto con possibile uscita immediata
⦁ [Bug] In caso di non utilizzo del campo SUFFIX (Campo vuoto) nei FLAT con camere a COLORI o DSLR non veniva salvato il FIT e veniva generato errore con impossibilità di eseguire i FLAT